| Feature |
Specification |
| Pump Volume per Stroke |
100 mL air |
| Pump Models |
AP‑20 (standard), AP‑20CT (with mechanical counter) |
| Tube Protection |
Dual-layer, shatter-resistant |
| Tube Range |
Measures up to ~400 gases/vapors via 250+ tube types |
| Accuracy |
Colorimetric reading directly from tube scale; recalibration through tube catalog |
| Power Source |
Hand-powered; AP‑20CT uses AA batteries for counter |
| Weight |
AP‑20: ~290 g; AP‑20CT slightly heavier with counter |
| Accessories |
Extension hoses (up to 20 m), hot-air probe (up to 600 °C capable), tip cutter |
⚙️ Component Breakdown
- Sampling Pump (AP‑20 / AP‑20CT): Reproducible 100 mL stroke, ergonomic non-slip grip, integrated ceramic tip cutter, model with counter for multi-stroke sampling
- Detector Tubes: Pre-filled reagent with scales; tube stain length correlates to gas concentration
- Accessories: Include hot-air probe (SF‑40) for high-temperature gases, remote hoses, soil/gas sampling rods, and tip cutter (B‑191) with fragment catcher
🧪 Product Range & Accessories
- Sampling Pumps: AP-20 series, AP-20CT with counter
- Hoses: SH‑5N/10N (up to 10 m), SH‑20N/C (20 m dual-tube)
- Probes: SF‑40 hot-air probe, SR‑200R extension rod for remote sampling
- Cutters: B‑191 tip cutter with built-in fragment container
- Others: Soil sampling kit (SPG‑1), glass syringes for high-temp/dilute sampling
📌 Applications
- Environment and workplace safety monitoring (e.g., SO₂, CO₂, H₂S)
- Emergency response and disaster relief operations (e.g., P‑50/UFO‑II H toxic gas kits)
- Environmental emissions testing (e.g., flue gas sampling: NOₓ, SO₂)
- Confined space or remote sampling using extension rods/probes
- Soil/gas leak detection in environmental surveys