Features
- Sensor and battery replacement
- Power on / off available
- Configuration via exclusive IR Link
SGT-P is a single replaceable gas detector designed to detect oxygen deficiency and the presence of toxic gas in the ambient environment. SGT-P is the replaceable type of gas sensor and battery. When activated, SGT-P continuously monitors ambient air for the presence of a specific gas and alerts the user to potentially unsafe exposure with LED, vibrating, and audible alarms in the event that gas concentration exceeds alarm set points.Enquire Now
| Model | SGT-P | |||
| Sensor Type | Electrochemical | |||
| Measuring Type | Diffusion Type | |||
| Case Material | Rubber Enclosure | |||
| Dimension | 54 (W) x 91 (H) x 32 (D)mm | |||
| Weight | 93g (Toxic), 104g (O2) / Battery, Clip included | |||
| Operating Temperature | -40℃~+50℃ (for CO, H2S, H2, NH3, and No2)
-35℃~+50℃ (for O2 and SO2) |
|||
| Operating Humidity | 5%~95% RH (Non-condensing) | |||
| Operating Life | 24 months, Based on 2 minutes of alarm per day | |||
| Event Log | Recent 30 alarms | |||
| IP | IP 67 | |||
| Alarm | Red Flashing LEDs (Light-Emitting Diode),
90dB audible alarm at a distance of 10cm, Vibration alarm |
|||
| Display | Liquid Crystal Display (LCD) | |||
| Battery | Manufacture : Vitzrocell, P/N : SB-AA02 (P),
System : Lithium Primary Battery, Nominal Voltage : 3.6V, Nominal capacity : 1.2Ah |
|||
| Components | Calibration Cap, Manual, Calibration and Test Certificate | |||
| Certification | ATEX | II 1 G Ex ia IIC T4 Ga | ||
| IECEx | Ex ia llC T4 Ga | |||
| CSA/UL | Ex ia llC T4 Ga
Class I, Zone 0, AEx ia IIC T4 Ga Class I, Division 1, Groups A, B, C, D, T4 |
|||
| INMETRO | Ex ia llC T4 Ga | |||
| PESO | Ex ia llC T4 Ga | |||
| etc. | RoHs2, RCM, REACH, WEEE, FCC | |||
High-quality product designed for durability, performance, and reliability, perfect for everyday use and long-term value.